Short answer: choose 314Ah when space is limited and you want the most energy per cell. Choose 280Ah when it costs less per kWh for the set you need and the extra energy is not essential. They are almost the same size, so one does not take more room than the other.

The specs side by side

EVE 280Ah CATL 280Ah EVE 314Ah CATL 314Ah
Nominal energy 896Wh 896Wh 1004.8Wh About 1004.8Wh
Size (mm) 173.7 × 71.7 × 207.2 173.9 × 71.7 × 207.2 173.7 × 71.7 × 207.2 174 × 71.65 × 207
Weight 5.49 kg ± 0.3 5.34 kg ± 0.3 5.6 kg ± 0.3 ≤5.51 kg

Figures are from our product listings. Confirm against the cell maker's datasheet before you finalise a design.

How much energy you get

Bar chart of nominal energy. 4 cells: 3.58kWh for 280Ah, 4.02kWh for 314Ah. 8 cells: 7.17 and 8.04kWh. 16 cells: 14.34 and 16.08kWh

Nominal energy is voltage × capacity, so a 16-cell 51.2V pack with 314Ah cells gives 51.2 × 314 = 16.08kWh. You will not use all of it. If you limit your system to 90% depth of discharge, for example, you get about 14.5kWh from 314Ah cells and 12.9kWh from 280Ah cells.

Cost per kWh

Bigger is not automatically better value. Here is what a 16-cell set costs in our store:

16-cell set Price (USD) Energy Per kWh
EVE 280Ah $1,130.75 14.34kWh About $79
CATL 314Ah $1,345.89 16.08kWh About $84
EVE 314Ah $1,420.67 16.08kWh About $88
CATL 280Ah $1,272.00 14.34kWh About $89

Prices were checked on 7 November 2026 and may change. Check the product page for the current price in your currency.

Things that matter more than the size

  • Your box and BMS. Our 51.2V box and 12.8V box are listed for 280, 304, 314 and 320Ah cells. A 200A BMS on a 51.2V pack allows about 10kW, whichever cell you choose.
  • Do not mix cells. Use the same capacity and brand throughout a pack.
  • Cycle life claims. Sellers quote different figures under different test conditions. Compare depth of discharge, current, temperature and end-of-life capacity, not the headline number.
  • Charging temperature. Do not charge LiFePO4 cells below 0°C, because lithium plating can raise the risk of an internal short circuit. Battery makers may set a narrower range, so follow your own battery's limits.

Quick decision

Your situation Better fit
You need the most energy from 16 cells 314Ah
You want the lowest cost per kWh right now Compare the table above
You are matching an existing 280Ah pack 280Ah, in a separate pack; ask your inverter and BMS maker about paralleling